dc axial fans tel: 425-222-5900 800-453-4569 www.mechatronics.com e-mail: sales@mechatronics.com fax: 425-222-5155 cooling simplified (40 x 40 x 10.3 mm) 1.57 x 1.57 x 0.41 inches construction: ul94v-0 pbt impeller & frame bearing option: ball bearing connection: awg 26, ul1061 lead wires frame: ribbed protection: thermal options: tachometer output or locked rotor alarm signal g4010 series 12 8 4 0 0.1 0.2 static pressure - mm of water 0.3 10 6 2 0.4 s e h m l air flow (m 3 /min) 1.26 0.01 (32 0.3) air flow 1.57 0.02 (40 0.5) 0.41 0.02 (10.3 0.5) 4x ?0.17 0.01 (4x ?4.25 0.3) model no. rated voltage v current ma speed rpm air volume max. static pressure (h 2 0) sound noise dba weight g 5 12 24 m3/min. cfm mm inch g4010s 5/12 90 60 - 4,000 0.13 5.00 1.70 0.07 21 12 g4010l 5/12/24 140 100 70 5,000 0.16 6.00 2.70 0.11 22 12 g4010m 5/12/24 240 150 100 6,000 0.19 7.00 3.70 0.15 28 12 G4010H 5/12/24 400 220 160 8,000 0.25 9.00 6.40 0.25 35 12 g4010e 12/24 - 350 250 10,000 0.32 11.00 9.90 0.39 41 12 12.15.14
|